Phasor K3-9.5kW Marine Diesel Generator – 1800 RPM, Standard Series
$30,492
☆☆☆☆☆ (0)
Severe commercial blackout risks threaten institutions, making Generac XG04045 Standby Generator essential, delivering 45kW of 120/240V single-phase electricity via an automotive 4.5L engine for uncompromising estate backup circuit security. - 45kW single-phase output powers corporate offices - 4.5
15145.00 USD
In stock
15145.00 USD
In stock
Sudden power line drops ruin cold storage inventory, making the Generac XG04045ANAX Commercial Standby Generator an indispensable operational safeguard for grocery stores and food processing warehouses. Generating 45 kW continuous power at 120V and 208V 3-Phase 60Hz, this liquid-cooled stationary plant powers three-phase refrigeration compressor racks, commercial dishwashers, and facility lighting networks without delay.
Constructed within an architectural-grade aluminum sound enclosure, this unit contains an industrial 4.5L four-cylinder engine engineered for continuous emergency service. The brushless alternator features 100 percent copper windings coated with Class H thermal insulation to prevent heat breakdown. Weighing 1930 lbs dry, the stationary unit mounts to concrete slabs with frame dimensions measuring 77 inches long by 34 inches wide by 45 inches high.
Key Features of Generac XG04045ANAX
Commercial contractors who buy Generac XG04045ANAX commercial standby generator systems obtain industrial commercial power equipment engineered for balanced polyphase distribution. The digital Evolution controller monitors incoming utility feeds, triggering immediate automatic transfer switch engagement the moment line voltage deviates from normal operational limits.
- 45 kW continuous three-phase power energizes heavy commercial kitchen cooktops and commercial refrigeration cases.
- 120V and 208V 3-Phase configuration balances electrical branch circuits to prevent motor phase unbalance.
- Low-speed 1800 RPM engine operation cuts mechanical friction and lowers noise emissions across property lines.
- Corrosion-resistant aluminum enclosure provides durability against coastal salt spray and harsh winter weather.
- XG04045ANAX electronic isochronous governor holds output frequency within 0.25 percent during full-load motor starts.
- Dual-fuel mechanical capability operates on clean municipal natural gas or bulk on-site liquid propane tanks.
- Evolution controller offers multilingual diagnostic menus and records up to 50 operational event logs.
- Automatic low-oil and high-temperature shutoff circuits halt ignition before internal bearing damage can occur.
Three-Phase Harmonic Regulation Sound Output
Producing 65 dB(A) at 23 feet inside its acoustic sound-attenuated housing, this standby generator prevents disturbance to neighboring commercial office spaces. Total harmonic distortion remains under 5 percent across all three electrical phases, holding frequency steady at 60 Hz. The brushless alternator absorbs high inductive startup surges from multiple walk-in freezer compressors, consuming 615 cubic feet per hour of natural gas at half load.
Pad Placement Transfer Switch Connections
Anchor the generator base to a poured concrete pad at least 5 feet away from all commercial windows, doors, and building air intakes. Exhaust gases exit through top-mounted silenced louvers straight into ambient air. The three-phase output terminals connect to automatic transfer switches using copper conductors, grounded back to the main building service entrance.
Stationary Usability Preventative Maintenance Procedures
Lift-off access panels provide service technicians unhindered entry to spark plugs, fluid drain hoses, and radiator caps. This stationary generator is not engineered for mobile trailer installation, unventilated interior parking structures, or high-voltage 480V industrial motor distribution centers.
- Check radiator coolant level and inspect battery electrolyte before each shift.
- Drain engine oil and install fresh synthetic lubricant every 200 runtime hours.
- Inspect ignition spark plugs and test transfer switch operation every 12 months.
Manufacturer Warranty Factory Pallet Inventory
Generac provides a 5-Year limited warranty covering the 4.5L industrial engine, brushless alternator, and Evolution control module. The freight shipment delivers the Generac XG04045ANAX generator core, factory-installed aluminum enclosure, flexible gas connection hose, warranty registration packet, and comprehensive instruction manual.
| SKU | GEN-XG04045-ANAX |
|---|---|
| Category | Generators |
| Shipping | Included in the price, worldwide Ships in 2–5 days, then 15–21 days in transit |
No reviews yet.
Sign in or create an account to rate this product and share your experience.
$30,492
☆☆☆☆☆ (0)
$29,700
☆☆☆☆☆ (0)
$23,514
☆☆☆☆☆ (0)
$5,274
☆☆☆☆☆ (0)