Bell & Gossett 104328 3PH Ecocirc XL 45-375 Iron Body Circulator
$4,680
☆☆☆☆☆ (0)
To keep primary chiller loops running, the base-mounted Bell & Gossett 6G utilizes a 60 HP four-pole motor spinning at 1800 RPM to feed a massive 13.5-inch nominal impeller smoothly. - 60 HP motor drives high-volume water - 1800 RPM speed reduces motor wear - 8 inch suction moves heavy volumes - 6
27040.00 USD
In stock
27040.00 USD
In stock
Review the 6G case configuration of the Bell & Gossett e-1510 6G 60 HP ODP, a base-mounted end suction pump with an 8 x 6 x 13.5 case size and 60 HP motor. Its 1750/1800 RPM four-pole speed and 13.5-inch full-diameter impeller reference support selection for primary chiller-loop and municipal water-transfer projects.
The official 6G submittal identifies 8-inch suction and 6-inch discharge ANSI 125 flanges as standard, with ANSI 250 flanges available. The ODP motor enclosure, 60 HP drive, and nominal impeller diameter do not establish hydraulic duty alone. Match the approved e-1510 curve, system head, flow requirement, suction conditions, and fluid properties before final equipment selection.
Key Specifications of the Bell & Gossett e-1510 6G End Suction Pump
- The 6G case size measures 8 x 6 x 13.5, defining the supplied base-mounted pump casing reference.
- An 8-inch suction and 6-inch discharge use ANSI 125 flanges as standard for piping compatibility review.
- A 60 HP motor establishes the listed drive capacity for primary chiller-loop or municipal-transfer system selection.
- The 1750/1800 RPM four-pole speed defines the supplied motor-speed reference for approved hydraulic duty evaluation.
- A 13.5-inch full-diameter impeller reference requires confirmation against the exact selected trim and performance curve.
- Open drip proof construction specifies the ODP motor enclosure for this 60 HP e-1510 configuration.
- Primary chiller loops and municipal water transfer are the stated application contexts for evaluating this assembly.
Hydraulic Performance and Application
The Bell & Gossett e-1510 6G is listed for primary chiller loops and municipal water-transfer applications. Its 60 HP motor, 1750/1800 RPM speed, and 13.5-inch impeller reference do not define an operating point. Select using the applicable e-1510 curve and approved duty. Confirm required flow, head, suction conditions, pressure, fluid characteristics, and piping losses before finalizing the configuration.
Installation and System Requirements
Confirm compatible three-phase electrical service, motor rotation, system curve, pressure requirements, and suction arrangement before installation. Verify that the standard 8-inch suction and 6-inch discharge ANSI 125 flanges match the planned piping. ANSI 250 flanges require an appropriately supplied configuration. Provide independent pipe support, then follow official e-1510 instructions for base mounting, alignment, electrical connection, and startup.
Service and Maintenance Considerations
Verify the 13.5-inch impeller reference against the exact submitted trim before ordering replacement components or evaluating hydraulic adjustments. The 6G assembly requires service access for the motor, coupling, seal, and rotating components according to official e-1510 documentation. Follow lockout, alignment, inspection, and post-service procedures. Do not use nominal impeller size as a substitute for the approved parts list or pump curve.
Why Choose the Bell & Gossett e-1510 6G 60 HP ODP
This configuration combines an 8 x 6 x 13.5 6G casing, 60 HP ODP motor, 1750/1800 RPM speed, and standard ANSI 125 flange connections. ANSI 250 flanges are available for an appropriate configuration. Buyers can compare these piping and motor characteristics for chiller-loop or municipal-transfer systems, then validate selected impeller trim and hydraulic duty through the e-1510 performance curve.
Warranty and Support
Bell & Gossett commercial pumps carry a 1-Year Limited Warranty against defects in materials and workmanship. Coverage begins at installation and ends no later than eighteen months from shipment, whichever occurs first. Seals, gaskets, elastomers, coatings, and other wear parts are excluded unless sales documentation states otherwise. Mulmotor provides product-information support before purchase and assistance with order-related questions.
Before Ordering the Bell & Gossett e-1510 6G End Suction Pump
Before ordering, verify that your chiller-loop or municipal-transfer project requires an 8 x 6 x 13.5 6G casing with 8-inch suction and 6-inch discharge flanges. You should select flow and head through the applicable e-1510 curve, then confirm the 60 HP ODP motor, speed, flange class, impeller trim, fluid requirements, pipe support, and service clearance.
| SKU | 6G-E-1510 |
|---|---|
| Category | Booster Pumps |
| Shipping | Included in the price, worldwide Ships in 2–5 days, then 15–21 days in transit |
No reviews yet.